[Prev][Next][Index][Thread]
Re: ,)
-
To: tesla-at-grendel.objinc-dot-com
-
Subject: Re: ,)
-
From: jim.fosse-at-bdt-dot-com (jim fosse)
-
Date: Tue, 27 Feb 96 00:08 PST
-
>Received: from bdt.bdt-dot-com (root-at-bdt-dot-com [140.174.173.10]) by uucp-1.csn-dot-net (8.6.12/8.6.12) with SMTP id BAA04177 for <tesla-at-grendel.objinc-dot-com>; Tue, 27 Feb 1996 01:09:00 -0700
>Guys, I've been running my 2 rolled caps at 12kv for close to a year
>without a burnout. The first one I ran alone for about 9 months.
>That cap sat in oil for about 2 months or more before I ever used it.
>The second one sat for at least a month, but was hooked up in series
>with the first when it was first fired. Do you think that the oil
>saturating the roll is preventing a burnout?
>
>Of course I am using the 2 rolled caps for a stand for the primary now
>that I have my 2 commercial caps. :)
>
>
>Mark R. Napier
>napier-at-cats.ucsc.edu
>
>
&*&*((^ I'm jellous. Can I have one:) or two or ...
What dialectric did you use? 1 0.060 polyethylene like I did as an expediant
method, or 3 0.030" layer like Richard Quick recomends?
jim