Guess I have something to say here:
> From: John H. Couture[SMTP:couturejh-at-worldnet.att-dot-net]
> Sent: Monday, December 01, 1997 11:27 PM
> To: Tesla List
> Subject: Re: Recycled: Measuring Coupling Coefficients
<snip>
> I agree that the K factor (coupling coefficient) appears to be independent
> of the frequency for Tesla coils. However, further research indicates the K
> factor is a number that depends on the type of operation. Refer to Terman's
> Radio Engineers' Handbook. For example, in radio circuits the K factor
> varies with the frequency because of the variable tuning capacitor.
> Changing this capacitor changes the operating frequency and changes the
> coupling. This means that a Tesla coil with a fixed capacitor would have a
> fixed coupling and be independent of frequency . However, if the TC
> capacitor is changed and the operating frequency changed the coupling would
> also be changed without changing the physical characteristics or geometry of
> the coil. Has anyone ever checked this?
My experiments suggest k is purely related to coil geometry and
proximity given that Ls and Lp are *fixed*, not "variables". If you
alter geometry of either coil or coil proximities to one another, Lp
and Ls don't change but k does and hence Lm must. It is worth noting
that unless you know how many turns you will be using on that 15 turn
primary, you can't pre-calculate k either.
Malcolm
> The mutual inductance test for K factor introduces two additional
> variables, Lp and Ls, to the voltage and current that is necessary to
> determine the Lm. This test would be less accurate compared to the other
> tests using only two variables. If all variables are measured to the same
> accuracy the other tests would have twice the accuracy of the mutual
> inductance test.
>
> As for the light bulb shown in the Tesla Coil Design Manual for the mutual
> inductance test, the non linearity of the bulb is not involved. This test
> uses a fixed current that is independent of the non linearity of the bulb.
> The fixed current is obtained by varying the primary voltage with a variac.
> This has the advantage that the mv in the secondary is the uh of the mutual
> iinductance so calculations are not necessary. This test is also safer
> because it operates at low voltage.
>
> Comments welcomed.
>