[Prev][Next][Index][Thread]

Re: TC Electrostatics (fwd)



> > Robert W. Stephens wrote:
 
> Greg,
> 
> In response to your specific questions regarding my MTC system.
> 
> *Input power 6.9 kVA (30 amps -at- 230 volts)
> 
> *Spark length 144 inches,  measured point-to-point, line of sight
>   horizontal shot to a metal   roof.  Have it on video and still photos with witnesses
>   who were there helping with the outdoor test last spring.
> 
> *Sec Frequency 87 KHz
> 
> *Sec inductance 50.0 mH
> 
> *Gap rate 400 pps, non-synchronous.
> 
> A photo of the twelve foot strike is posted with the .rws pictures at
> the nic.funet.fi site.  Look for the file MTCpics.doc (or something
> similar), it will tell you which photo to find it in.  These MTC pictures are all from
> that one evening's test.
> 
> Hope this helps.
> 
> regards,
> rwstephens

Thanks alot for the info!