Hi Steve,
What kind of precautions do you observe? What kind of spark gap
arrangement is it? (plain, trigatron, swinging cascade, field
distortion swinging cascade, irradiated field distortion swinging
cascade) electrode material, spacing between electrodes, hydrogen
purge after every shot, scope photo of a quenched waveform with
circuit parameters, temperature, preionization schemes?
Barry
-----Original Message-----
From: Tesla List +ADw-tesla+AEA-pupman-dot-com+AD4-
To: tesla+AEA-pupman-dot-com +ADw-tesla+AEA-pupman-dot-com+AD4-
Date: Sunday, September 06, 1998 10:43 PM
Subject: Re: Spark Gap Gasses Experiment
+AD4-Original Poster: Steve Rodway +ADw-Legion+AEA-bigfoot-dot-com+AD4-
+AD4-
+AD4-Tesla List wrote:
+AD4-
+AD4APg- Has anyone tried out gaps at higher preassure? I'd assume quenching
+AD4APg- would get better as the recombination time of the ions were
lowered.
+AD4APg- Higher
+AD4APg- preassure would most surely do that. At higher preassure the atoms
are
+AD4APg- packed more closely and possibility of collitions needed for
recombination
+AD4APg- would rise.
+AD4-
+AD4- At work we have a hydrogen spark gap with operates at up to 30atm
+AD4-pressure, it is not used with tesla coils, but it is in a capacitor
discharge
+AD4-circuit, and the quenching is INCREDABLE, we can operate it with
primary
+AD4-energies of 10's of joules per discharge with rep rates over 5KHz,
and even
+AD4-then it is not the gap which is the limiting factor, but the system
it is
+AD4-driving.
+AD4-
+AD4-