[Prev][Next][Index][Thread]
Re: 43" First light! - Dead Transformers :-(
At 07:12 19/09/98 -0600, you wrote:
>We did have a protection network in place but it was poorly
>constructed and "blew itself up". We had been operating without it when we
>got
>the primary/secondary strikes. Impatience :-(
>
>I am looking for suggestions for a good protection system for this coil. I
>will
>have 4 more NSTs available so I should be able to operate with 4-7
(120-210ma)
>depending on how many I can repair. I am considering unpotting them and
>puting them in oil.
I run a similar system, two 15 kV / 60 mA NSTs.
I use a protection circuit as advised by Malcolm Watts
See:
http://www.cobweb-dot-com.au/~dkfinnis/current_coil.htm
scroll down to see both circuit & parts used ;-)
The original 1K resistors where rated at 50W (3 of 17W wire-wound). I have
since replaced these with 100W versions mounted on heat-sink which are far
better (just be careful with insulation from heat-sink !!!).
Cheers,
Mark
http://www.cobweb-dot-com.au/~dkfinnis