Re: MOT Voltage Doubler correction



At 12:08 20/09/98 -0600, I wrote:

>that is a pulsed (50/60 Hz) voltage going from 0 to 4kV*2.8 = 11.2 kV.

Sorry, I made a miscalculation. Below is the corrected one:


that is a pulsed (50/60 Hz) voltage going from 0 to 2kV*2.8 = 5.6 kV.