Marco,
Seems like it would be easier amd more flexible to keep your existing pig
and add a (custom made with several taps?) transformer or autotransformer
in the primary to lower the voltage into your pig. Or, get a big variac
and add a mechanical stop to prevent the knob from turning past whatever
maximum voltage you want to limit the variac output to.
--Steve
<SNIP>
> Well, luckly money is not an issue here for me (this time!). But I am
> seriously considering to have a customer pig wound to get 10 kV AC
instead
> of 20 kV AC from it. As I wrote before, 20 kVA rectified and with
resonant
> charging lead me into the 60 kV area (!). 30 kV would be easier to manage
> :)
>
>
>
>
>
>
>