[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: NST frequency
Original poster: "Kevin Ottalini by way of Terry Fritz <twftesla-at-qwest-dot-net>" <ottalini-at-mindspring-dot-com>
Rob:
I see this effect with my Marx generator ... after I discharge it, I
have to cycle power
to get the inverter going again, but it appears to be backlash (ringback)
from the discharge
not EMP. I don't believe though that Darin is to this stage yet ...
Unfortunately, disconnecting the inverter from a live Cockroft is a sure
recipe for
damaging the Cockroft ... from years of experience. Building 10,000
Cockroft
Multipliers and Inverters kinda takes you through every failure scenario at
a few times.
Best,
Kevin
----- Original Message -----
From: "Tesla list" <tesla-at-pupman-dot-com>
To: <tesla-at-pupman-dot-com>
Sent: Wednesday, August 01, 2001 6:03 PM
Subject: Re: NST frequency
> Original poster: "Area31 Research Facility by way of Terry Fritz
<twftesla-at-qwest-dot-net>" <rwstephens-at-hurontario-dot-net>
>
> I believe that Darin's problem of the inverter going stupid is being
caused by
> EMP when he discharges his Multiplier. It could well be that there is
enough
> increase in EMP from 4 stages over 3 that he thresholds into this problem.
I
> built a tabletop Cockroft Walton multiplier that achieves 150 KV on top
from 5
> kVAC input in the lab and the first time I discharged it into a grounded
wand
> it made a VCR in the same room lock up so badly it had to be left
unplugged
> overnight to recover.
>
> Physically disconnecting the inverter and also powering it down prior to
> discharging the multiplier may be helpful, although no guarantee of saving
the
> inverter from catastrophic damage. Shielding and bypassing of all leads
in and
> out of the inverter may help.
>
> Rob
> >