[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: NST w/20khz sec.



Original poster: "by way of Terry Fritz <twftesla-at-qwest-dot-net>" <Parpp807-at-aol-dot-com>

In a message dated 3/19/02 9:14:21 AM Central Standard Time, tesla-at-pupman-dot-com 
writes:

> I've seen small NST on ebay with 20khz output.  would this
>  kind of transformer work with a static gap?  i think they were
>  15kv/20ma/20khz.

Hi Larry,
A 15 kV/ 20 mA NST will work with a static gap altho the 20 mA is kinda wimpy.
I have no idea what is meant by a NST with 20 kHz output?
The HV output freq will be the same as the AC line freq--60 Hz.

Cheers,
Ralph Zekelman