[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
new cap, sucker gap :))
Original poster: "Steven Ward by way of Terry Fritz <twftesla-at-qwest-dot-net>" <srward16-at-hotmail-dot-com>
Hi all,
I was tho guy who had all of that trouble awhile ago with the GE42l caps. I
now have some CD caps(1600v .22uf). Im using 1 string of 15 with a 12/60
PSU. These caps are tough! I also gave the Gary Lau sucker gap another
shot. I had actually built it for my large 2000w coil, but i was testing it
on this coil. This gap is grrrreat! Im gettin 36" sparks from my small
coil, and the safety never fires! With my RQ gap i could only get about 32"
and the safety would fire. But the sucker performs flawlessly. I did try
it as a blower gap, but i had some problems with a power arc forming and
loosing lots of performance. The sucker now uses a dimmer to control it, i
was amazed that it worked! I have it set to about 70% for best arcs.
I also have a little interesting topic to bring up. While using a breakout
point pointed at a un-grounded sphere, a good charge will be left on the
sphere after i turn off the coil! I was thinking some kind of rectification
was going on? The sphere is on a pair of buckets so its well away from
ground. So what is going on here? This seems to support the idea of DC in
the output of the coil. I dont know too much about all of this so thats why
im interested. Ive also had a metal lawn chair give me a really bad zap
after running my large coil, letting it arc to it. I think the thick paint
gave it more capacitance? So whats the deal? is this anything new or just
old news?
Steve Ward.