Original poster: "Dr. Resonance by way of Terry Fritz <teslalist-at-qwest-dot-net>" <resonance-at-jvlnet-dot-com>
Your ASRSG is way too fast. Use a 1725 RPM 1/2 HP motor with 12 electrodes
on a 11 inch dia. circle pattern on a 12 inch dia. piece of 1/2" thick G-10.
Set your power reactor so the PT output power is 30 Amps at 120 VAC on the
pri side (3.6 kVA).
Proper cap size would be around .05 to .06 MFD with a Geek Group cap bank.
Dr. Resonance
Resonance Research Corporation
E11870 Shadylane Rd.
Baraboo WI 53913
>
> I am in the process of building the "Terry blake ARSG gap". I will have a
> 19,500 RPM motor on it, but, thats WAY too fast, so i will put a dimmer
> switch on it (i was going to run the coil, and adjust it while it was
> running to get the best output. Probally around 4000 rpm). I am running a
> 14.4 KV 1.5KVA pt and i was planning to use 2 strings of 10 geek group
caps
> for a total of .03UF. Should i use more caps? And, is that rating for the
> cap good?