All Electronics used (and may still do) have 400 Hz variacs...Just don't try
to operate them at 120V at 60 Hz...
----- Original Message -----
From: "Tesla list" <tesla-at-pupman-dot-com>
To: <tesla-at-pupman-dot-com>
Sent: Thursday, June 19, 2003 8:35 PM
Subject: Re: Higher Mains Frequency
> Original poster: "Ed Phillips by way of Terry Fritz <teslalist-at-qwest-dot-net>"
<evp-at-pacbell-dot-net>
>
> Tesla list wrote:
> >
> > Original poster: "WIZZARD . by way of Terry Fritz
<teslalist-at-qwest-dot-net>"
> <pbobyk-at-hotmail-dot-com>
> >
> > I believe aircraft use 400 Hz distribution systems so the transformers
can
> > be lighter.
>
> Correct. Some have used other frequencies as well; I designed the
> radar in the F-106 (long extinct) and we used 1600 cycles there. Space
> station uses even higher I believe.
>
> Sixty Hz tranformers will work fine on 400~ if you take into account
> the higher leakage reactance.
>
> Not long after WW2 some surplus stores were trying to sell 400~
> transformers with the statement "conservatively rated at 400~" with the
> strong implication that would work on 60~ just as well. Caveat
> emptor...
>
> Ed
>
>