[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Paralleling Filament Transformer VTTC
Original poster: "Steven Ward by way of Terry Fritz <teslalist-at-qwest-dot-net>" <srward16-at-hotmail-dot-com>
Dan,
there is no reason that wont work, and there may be a benefit, but really
if you can control the transformers independantly with variacs (too much
hassle). Here what i did for my 10V 20A supply. Fair Radio Sales (do a
search for the website) sells a 20V 20A transformer for $20 i
believe. They dont tell you that it has essentially 2 primary coils. And
when you series and phase them properly, you get down to about 11v. Then,
open up the casing and its easy enough to take off about 3 turns of the
secondary as it is exposed when you remove the copper band and some
insulation that wrap around the core and coils. So now i have a
transformer that puts out 9.9 - 10.3 V depending on my line voltage. At
120 in, its exactly 10.0v output ;) And the $20 is pretty good for such a
transformer! And since its rated 400W, this 200W load is nothing for it,
so it can run cool all day long i bet. Hope this may help.
Steve Ward.
>From: "Tesla list" <tesla-at-pupman-dot-com>
>To: tesla-at-pupman-dot-com
>Subject: Paralleling Filament Transformer VTTC
>Date: Mon, 03 Mar 2003 12:06:00 -0700
>
>Original poster: "Mccauley, Daniel H by way of Terry Fritz
><teslalist-at-qwest-dot-net>" <daniel.h.mccauley-at-lmco-dot-com>
>
>
>
>Regarding my dual 833A VTTC, is it more beneficial to parallel my 10V, 10A
>filament transformers or to have each one
>ran by its own filament transformer. I tried to look for a 10V, 20A
>transformer but couldn't really find one off the shelf
>with less than a few month lead time and I'm too lazy right now to wind my
>own.
>
>Thanks
>