[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Tesla Coil RF interference (humidity)
Original poster: "Jim Lux" <jimlux-at-earthlink-dot-net>
> Ok, I guess this is off topic, but to bring it back to
> topic...my coils don't mind the humidity much. I
> guess it is because I tend to run them indoors most of
> the time, with the the AC on to cut down humidity. It
> would be nice to have a hygrometer and do some real tc
> humidity spark length comparisons.
>
> -Brett
Radio Shack, etc., often has hygrometers for cheap as they change models and
physical configurations. The usual run of the mill solidstate sensors are
good to a few percent. Sensirion (http://www.sensirion-dot-com/ )was mailing
out samples for their humidity sensor chip. For instance: the SHT11 is a
digital (2 wire) output...Single chip sensor module, fully calibrated with
digital 2-wire output. 0-100%, -40 to 120°C, fully immersible, accuracy +/-
3.5%RH, +/- 0.5°C -at- 25°C, response time humidity sensor 4s
You can also do the wet bulb/dry bulb thing and look it up in a
psychrometric chart. If you've got a thermometer with any sort of probe
(i.e. a standard alcohol thermometer or a cooking thermometer or an
electronic thermometer with the probe) and a wet shoelace, you're all set.