[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Edgewound primary
Original poster: "Bert Pool" <bert.tx-at-prodigy-dot-net>
I have to second Kevin's observations. I've put over 200 KV on a flat
aluminum flashing strip about 12 to 15 inches wide and had NO corona on the
edges! A 3 inch primary strip with a puny 15 kv, or so, will have
absolutely no corona.
Bert Pool
At 05:14 PM 10/17/2004 -0600, you wrote:
>Original poster: Bigggcoil-at-aol-dot-com
>Rick
>
> I have made many aluminum ribbon primaries in the past, all worked
> well. Corona is not an issue because the ribbon spiral acts more like a
> flat plate in terms of corona, the E field is evenly distributed accross
> the ribbon. I have never had a corona issue in any of my coils up to 14
> kV primary voltages. I'd do it.
>
>Kevin E.