Hi Paul,
I would disconnect the computer equipment when running the coil just in
case. When I run my coil in the garage under the house my messages on the
answering machine and the stored numbers on the phone which are both in the
house above are erased.
Claude.
----- Original Message ----- From: "Tesla list" <tesla@xxxxxxxxxx>
To: <tesla@xxxxxxxxxx>
Sent: Saturday, May 07, 2005 6:38 AM
Subject: Re: EMI Filters
Original poster: "Paul B. Brodie" <pbbrodie@xxxxxxxxxxxxx>
Karl,
I'm, sorry, my hands were typing before my mind was functioning! The EMI
filter is wired between the variac output and the coil driver. The volt
meter is "behind" the EMI filter along with my house wiring. Now I'm
concerned about running my Tesla Coil from my house supply as I have a ton
of sensitive computer equipment in the house. I do have a separate RF
ground outside. It is an 8 ft. ground rod in the ground just outside of
the garage. I have another 20A EMI filter and I think I will wire it in
between the wall outlet and the variac so that I have 2 EMI filters with
the variac in between them.
Paul
Think Positive
----- Original Message -----
From: "Tesla list" <<mailto:tesla@xxxxxxxxxx>tesla@xxxxxxxxxx>
To: <<mailto:tesla@xxxxxxxxxx>tesla@xxxxxxxxxx>
Sent: Friday, May 06, 2005 2:18 PM
Subject: Re: EMI Filters
> Original poster: Karl Lindheimer
<<mailto:karl@xxxxxxxxxxxxxxx>karl@xxxxxxxxxxxxxxx>
>
> Hi Paul,
>
> If I understand correctly, you state that the EMI filter is between the
> wall outlet and the variac? If that is the case, the filter will only
> reduce any back EMI from reaching the wall outlet and the rest of the
> connected house wiring on the same circuit. The variac and meter are >
still
> exposed to the EMI from the coil. My flyback transformer experiments >
also
> created huge RF/EMI necessitating that I disconnect any >
valuable/sensitive
> equipment from the AC line. I ended up building a robust simple power
> supply to spare my lab grade bench supply.
>
> Karl
>
> On May 5, 2005, at 1:20 PM, Tesla list wrote:
>
>>I have a 20A EMI filter wired in reverse between the wall outlet and my
>>variac. I have a volt meter attached to the variac outlet.
>>
>>I was driving one of my ignition coils with a 600 watt dimmer in series
>>with a 2mF cap. As I powered up the variac, I could read the voltage
>>increasing on the volt meter all the way up to 120V. When I turned up >>the
>>dimmer, the voltage indication on the volt meter went haywire when the
>>coil began sparking. If I drew the ground away from the HV output, the
>>volt meter would stabilize as soon as the sparks stopped.
>>
>>What have I missed here? This isn't normal, is it??!! Could the
EMI >>filter
>>be bad?
>>Paul
>>Think Positive
>
>
>