Original poster: Greg Leyh <lod@xxxxxxxxxxx>
Hi Antonio,
Original poster: "Antonio Carlos M. de Queiroz" <acmdq@xxxxxxxxxx>
A DRSSTC can be made to generate almost the same waveforms of a capacitor-discharge system, but the systems are different. The fundamental difference is that a capacitor-discharge system operates using the zero-input response of the network, and the DRSSTC uses the zero-state response, with a sinusoidal (or square wave with negligible difference) input.
I have a DRSSTC designer/simulator here (sstcd): http://www.coe.ufrj.br/~acmq/programs (Still can't design systems operating exactly at the resonances, but can simulate them.)