Re: Potential Transformer



Original poster: "D.C. Cox" <resonance@xxxxxxxxxx>



If you haven't wound the sec yet, go to 24 AWG 180 or 200 degree wire ---
around 1,400 turns with aspect ratio of 4.5:1.

I've run these PTs at 4 kVA keeping run time to 45 sec or less.

Dr. Resonance

I was lucky enough to procure a Westinghouse PT-15 from Dr. R (Thanks !) at the Cheesehead teslathon. From what I could gather it's a 1750 VA, 120v to 14.4 KV unit. First I was wondering how far I can push this unit? I was hoping to get up to 4 KVA on a 6" X 32" sec. with #20 wire. On another note I was wondering how to go about conditioning the output? RF filtering etc. Is a modified terry filter what I need? As always thanks in advance.

Mike.