[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: My 4 inch tesla coil - part 2
Original poster: "david baehr" <dfb25@xxxxxxxxxxx>
having that connection of the inner pri turn sticking up like that
is not good , connections should run below,....that goes for your
pri. tap point also ,
the under side of my primary has open access , so nothing is
prodruding above to create corona and possible flash over to the
sec.,..... on my 4" coil
From: "Tesla list" <tesla@xxxxxxxxxx>
To: tesla@xxxxxxxxxx
Subject: My 4 inch tesla coil - part 2
Date: Mon, 16 Apr 2007 12:27:10 -0600
>Original poster: "Hydrogen18" <hydrogen18@xxxxxxxxxxxxx>
>
>I've made the suggested improvements to my primary coil, which you
>can see here:
>
><http://www.hydrogen18.com/projectlogs/hivolt/4inchtesla/>http://www.hydrogen18.com/projectlogs/hivolt/4inchtesla/
>
>and the results here:
>
><http://www.hydrogen18.com/projectlogs/hivolt/4inchtesla/4_15_2007/>http://www.hydrogen18.com/projectlogs/hivolt/4inchtesla/4_15_2007/
>
>Questions arising from such:
>
>- I've got rather active arcing from the primary to the secondary
>now. How do I solve this. More layers of shellac on the secondary?
>Even if I eliminate the breakout point from the secondary that I
>unintentionally created, I think it's just going to arc from the
>first turn to the secondary.
>
>- Is there any hope of repairing the secondary? Although it has tiny
>burnt spots on it, it doesnt seem dead yet..I'm getting pretty good
>performance. No shorted turns im guessing. Can I sand the carbonized
>areas off with high grade sand paper before re-shellacing?
>
>- Before anyone mentions it, yes I'm still using the same terrible
>spark gap. I don't think that's much of a concern at the moment
>given my other problems.
>
>Eric
>
>
----------
<http://g.msn.com/8HMAENUS/2749??PS=47575>Mortgage rates near
historic lows. Refinance $200,000 loan for as low as $771/month*