[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

SGTC



Original poster: Frank <fxrays@xxxxxxxxxx>

An interesting question for the group:

Which circuit makes a better SGTC and why?

1) The cap in parallel with the HV transformer and the spark gap in series with the TC primary

OR

2) The spark gap in parallel with the HV transformer and the cap in series with the TC primary

OR

3) The SG in parallel with the HV transformer and caps in series with EACH side of the TC primary

I have plans dating back 100 yrs to the present and all configurations are used for small and large coils. There does not seem to be any preference and I have circuits using 20 KV transformers with all options above.

The gap in parallel configuration seems to be slightly more present in designs but not by a large margin.

The SG in parallel adds some over volt protection to the HV xfmr but also the risk shorting the transformer is present if the gap is left closed for any amount of time.

The third option completely isolated the TC primary from the HV transformer making it by far the safest for shock hazards.

Thanks, Frank