[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
SGTC
Original poster: Frank <fxrays@xxxxxxxxxx>
An interesting question for the group:
Which circuit makes a better SGTC and why?
1) The cap in parallel with the HV transformer and the spark gap in
series with the TC primary
OR
2) The spark gap in parallel with the HV transformer and the cap in
series with the TC primary
OR
3) The SG in parallel with the HV transformer and caps in series with
EACH side of the TC primary
I have plans dating back 100 yrs to the present and all
configurations are used for small and large coils. There does not
seem to be any preference and I have circuits using 20 KV
transformers with all options above.
The gap in parallel configuration seems to be slightly more present
in designs but not by a large margin.
The SG in parallel adds some over volt protection to the HV xfmr but
also the risk shorting the transformer is present if the gap is left
closed for any amount of time.
The third option completely isolated the TC primary from the HV
transformer making it by far the safest for shock hazards.
Thanks, Frank