[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TCML] measure VDG voltage
In actual practice, it's approximately 1 megaVolt per meter of spark
discharge between large dia electrodes.
For smaller machines up to 30 inch dia. spheres, use 26.5 kV / cm as an
accurate measurement.
We use a generating field mill voltmeter to actually measure the
potential. 26.5 kV / cm is the usual outcome for small and medium size
machines.
Dr. Resonance
Physicist
www.resonanceresearch.com
> Can anyone suggest me suggest a method to measure the voltage present on a
> topload of a Van de Graaf generator?
>
> Thank a Lot.
>
> Vladi
>
>
>
> Vladimiro Mazzilli
> Ricerca & Sviluppo
> Aros Srl
> Via Somalia 20
> 20032 Cormano (MI)
> Tel. +39 02 66327266 - Fax. +39 02 66327528
> email: V.Mazzilli@xxxxxxx
> Web: http://www.aros.it<http://http://www.aros.it>
> -----------------------------------------------------------------------------------------------------
> Chi riceve il presente messaggio e` tenuto a verificare se lo stesso non
> gli sia pervenuto per errore. In tal caso e` pregato di avvisare
> immediatamente il mittente e, tenuto conto delle responsabilita`
> connesse all'indebito utilizzo e/o divulgazione del messaggio e/o
> delle informazioni in esso contenute, voglia cancellare l'originale
> e distruggere le varie copie o stampe.
>
> The receiver of this message is required to check if he/she has received
> it erroneously. If so, the receiver is requested to immediately
> inform the sender and - in consideration of the responsibilities arising
> from undue use and/or disclosure of the message and/or the information
> contained therein - destroy the original message and any copy or printout
> thereof.
>
>
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxxxxxx
> http://www.pupman.com/mailman/listinfo/tesla
>
Dr. Resonance
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla