Dolph's AC-43 is the best you can use. It is especially formulated to use
in power transformer winding and has a high punture voltage. Also excellent
anti-tracking properties which is good engineering practice for HV coils
operating at RF frequencies. It is also excellent for sealing out any
moisture.
I usually gently heat the windings for 3 hrs with 3 heat lamps, and then
apply the varnish while the coil is still warm. The gentle heat drives out
any moisture prior to winding. Use a thermometer to set temp approx 150
degrees F. for 2-3 hrs. Another good idea is to preheat the coilform for 30
minutes just prior to winding --- drives out a moisture.
I carry it in 5 gallon cans and can usually spare a quart if you need some.
Contact me off-list.
Dr. Resonance
On 3/19/08, Mike H <mike8675309@xxxxxxxxx> wrote:
>
> Bart,
>
> On the question of the coating that you discussed, Is there an
> electrical, or other performance behavior that has you preferring
> marine varnish? Or is it just a question of for the application, you
> want to make sure you coat things fully, and thus based on price, the
> marine varnish simply makes more sense with little to no downside?
>
> Thanks
> Mike
>
> > Considering our outer layer "coatings" (and I personally don't like
> > polyurethanes but prefer marine spar varnish which to me is the best
> > coating for the price), the coating itself protects outside issues that
> > can cause turn to turn shorts, but the turn to turn voltage issue is
> > dependent on the wire insulation. I've never heard mention a problem
> > with that.
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxxxxxx
> http://www.pupman.com/mailman/listinfo/tesla
>
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla