Hi Simon,As far as noticeable losses, sure. But, build it for NST protection. That is it's purpose. Make sure you use only the number of MOV's for a 9kV NST. If you build it for 15kV, then the MOV's are not protecting the 8.5kV NST. Yes, you would have the RC filtering, but not the MOV back up.
Take care, Bart Simon Dodd wrote:
Hi Guys,So I have finally bought my Terry filter parts, my question is, I have an 8.5kV NST but can I build a terry filter for a 15kV NST without any noticeable losses? or should I stick to the 9kV rated option.Thanks Simon _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxx http://www.pupman.com/mailman/listinfo/tesla