Hi All,
Does anyone know the usual primary turns (240v side) on a 10KVA pig and the
wire gauge? I have a dry core with 36.875"^2 area and am looking at Finn
Manner's transformer project page.
http://www.hvtesla.com/radartransformer.html This is a heavy core! According
to Finn, turns equal K=1.6 for 60hz (K* E)/Area so(1.6*240)/36.875" to fully
magnetize the core. This would be only 10.41 turns. Yikes. Is that right?
Thanks,
Jim Mora
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla