[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] charging reactors



David Rieben skrev:
Hi Jim H., Jim M.,

I think Jim Mora's idea of using the HV side of a PT or a
pig and ignoring the LV side would be a good solution to
this situation. However, IIRC, the original poster of this
thread was looking for something that could withstand
10 to 20 kV AND 1 to 2 amps. So, that would probably
leave out a PT or a SMALL pig. Maybe the HV side of
a 15 or 25 KVA, 14,400 volt pig would fit the bill?

David Rieben
Except for the air gap that is needed in the core to keep it from saturating due to the DC nature of the pulsed current it is passing.

Cheers, Finn Hammer
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla