[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TCML] Terry Filter Gound
The NST mains ground goes to mains earth
Every thing from the HV side including the safety gap Tery filter goes to Actual earth / ground / stake in the soil
________________________________
From: Simon Dodd <simon@xxxxxxxxxxxxxxxx>
To: Tesla Coil Mailing List <tesla@xxxxxxxxxx>
Sent: Tuesday, 10 March, 2009 19:08:54
Subject: [TCML] Terry Filter Gound
Hi Guys,
I'm a little bit confused about the ground from the Terry Filter. All the schematics and pictures I have seen have indicated connecting the ground of the safety gap to RF ground and also running it back to the NST ground.
However everything else I have read has stated expressly not to connect the NST to the same RF ground as the Tesla coil. The only thing I can think of is to not connect the NST to the mains earth and keep it only on the RF ground.
Thanks
Simon
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla