[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TCML] (no subject)
If you contact me off-list I can email you a complete set of plans for a 12
kV 30 mA powered coil. It uses a flat primary as inverted V type primaries
can produce over coupling and actually give you
less spark length --- it also stresses your pri cap.
Dr. Resonance
On Sat, Feb 27, 2010 at 1:28 PM, Miles Mauldin <mmauldin@xxxxxxxxxxxxx>wrote:
> Looking for some guidance. I am an oldbe/newbe. My last effort was in the
> mid 70's, though impressive not stellar. My goal this time is stellar! I
> have tried to design may coil with upgrades in mind. My questions are
> regarding the size of the primary and secondary coils. I am starting with 2
> - 12Kv, 30ma NSTs and plan on adding 2 more later, total of 8 if it will
> work. If I can find the other upgrades I would like (pole pig, 30+amp
> variacs, etc...), I agree new coils would be necessary but for the interim,
> with NSTs, would a 4.5" or 6" be better for the secondary. And is there a
> significant difference between flat or inclined primaries?
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxx
> http://www.pupman.com/mailman/listinfo/tesla
>
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla