[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: [TCML] Questions on the Freau SRSG Phase Controller
John,
Thanks never realised that. SRSG's using a modified 'ordinary' motor and
phase controller are a big undertaking for a coiler as there are so many
deciding factors (the width of flats, capacitor size etc.) but the end
result is worth it in performance.
Regards
Phil
www.hvtesla.com
-----Original Message-----
From: tesla-bounces@xxxxxxxxxx [mailto:tesla-bounces@xxxxxxxxxx] On Behalf
Of Futuret
Sent: 24 September 2010 23:17
To: tesla@xxxxxxxxxx
Subject: Re: [TCML] Questions on the Freau SRSG Phase Controller
Phil,
I seem to remember that 240 volt motors need only 1/4 the amount of
capacitance of that needed by a 120 volt motor. I assume your 2HP motor
uses 240 volts. If your 2HP motor was a 120 volt motor, maybe it would need
496uF. Then if we divide 496 by six (to bring it down to a 1/3 HP
situation), we get 83uF. Well that still doesn't equal 195uF, but each set
up tends to be a little different anyway.
John
-----Original Message-----
From: Phil Tuck <phil@xxxxxxxxxxx>
To: 'Tesla Coil Mailing List' <tesla@xxxxxxxxxx>
Sent: Fri, Sep 24, 2010 2:37 pm
Subject: RE: [TCML] Questions on the Freau SRSG Phase Controller
Mike wrote > I use a 1/3 hp G.E. 3600 rpm motor modified for synchronous
operation. The gap has four flying electrodes and two stationary. The
phase controller consists of 195 uF of caps ,
--------------
That is interesting, as it seems the capacitor size is not scaled upwards as
the motor HP increases. My 2HP SRSG uses 124uF, yet Mike uses 195uF on a
motor that is only 1/6 of the power.
Phil
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla
_______________________________________________