Hi,
last year I did some experiments on this topic. I also noticed at this
time, that nearly no information is available about saturable reactors on
the TCML. In my experiments I replaced the normal air gapped ballast
inductor of my PT powered medium coil with 200bps SRSG by a big saturable
inductor. The results were very interesting but I stopped to investigate
this further. Maybe sometime in future I will continue experiments. I
made 2 videos, the first one shows the setup I used. The winding on the
central leg of the reactor is the "work" winding and the 2 outer legs,
connected in series, is the control winding. Heres the setup video:
http://www.youtube.com/watch?v=JBNglLIUpRE
And here it is running:
http://www.youtube.com/watch?v=XZn4bZOKS4U
Best Regards,
Stefan
----- Original Message ----- From: "David Speck" <Dave@xxxxxxxxxxxxxxxx>
To: "Tesla Coil Mailing List" <tesla@xxxxxxxxxx>
Sent: Sunday, October 30, 2011 8:28 PM
Subject: [TCML] Saturable reactors for TC Current limiting?
Anyone have any experience using a saturable reactor to limit TC current
draw on potential or MOT transformer stacks in disruptive TC
applications?
I thought I was tole once by a "prominent" authority in the TC business
that they didn't work well.
I know I have a 5 kW slide choke "somewhere". Just can't lay my hands
on it at the moment.
Dave