[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TCML] MOT stack replaced with PT, performance gone
Greetings
An aspect I'd consider is resonance with the leakage inductance and the
primary cap in the MOT system. Magnetically Shunted MOT's will have much
higher leakage inductance ( I think at least 6Hy per MOT) than the PT
leading to significantly different dynamic charging of Cp with the PT I
think
Rgds
Ted in NZ
-----Original Message-----
From: SusaX2 X2
Sent: Thursday, July 12, 2012 1:56 PM
To: Tesla Coil Mailing List
Subject: [TCML] MOT stack replaced with PT, performance gone
Hi,
recently my 4MOT-stack died and I replaced it with a PT.
I expected quite a performance gain, since it puts out twice the power of
the 4 MOT's.
But the completely opposite happened,
from streamers well over 1 meter to feeble 10cm sparks.
I also noticed the 200BPS SRSG fires very week, despite adjusting phasing
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla