[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] DC rating for 7KV5 transformer



Ah, I take it you bought these on ebay? 


Anyway I recomend you get some MMC caps part number CDE 942C20P15K, you should need like 11 or something like that as you can probably get away with a single string. 


I am trying to put together a group buy for these, or a different value CDE cap within the next few months if you want to wait. If not ebay has them. 



Thanks, 
John "Jay" Howson IV 


"Why thank you, I will be happy to take those electrons off your hands." 

----- Original Message -----
From: "Scott Moseley" <scott@xxxxxxxxxx> 
To: "Tesla Coil Mailing List" <tesla@xxxxxxxxxx> 
Sent: Sunday, March 11, 2012 8:07:01 PM 
Subject: RE: [TCML] DC rating for 7KV5 transformer 

Thanks for your quick reply. The caps were; 

ASC SHV24 
0.010MFD +/- 10% 
10Kv WVDC 

As I said, "were". They're now crispy, and make a cool light bulb when hooked up to power. For the few mins the coil was running, it sounded ANGRY. But I STILL can't get streamers from the top load. 



-----Original Message----- 
From: tesla-bounces@xxxxxxxxxx [mailto:tesla-bounces@xxxxxxxxxx] On Behalf Of jhowson4@xxxxxxxxxxx 
Sent: Sunday, March 11, 2012 7:53 PM 
To: Tesla Coil Mailing List 
Subject: Re: [TCML] DC rating for 7KV5 transformer 

You need to look at the RMS current rating for the capacitor, not just the voltage rating. 
As well as the peak current rating, is the cap rated for pulse duty? 

Also pay attention to the type of dielectric inside the capacitor, polypropylene is the best. 


for a static gap i would guess a 0.01uf cap, and for a SRSG perhaps .02. 
I usually shoot for tipple the RMS voltage as the cap voltage. 

What caps were you using out of curiosity ? 



Thanks, 
John "Jay" Howson IV 


"Why thank you, I will be happy to take those electrons off your hands." 

----- Original Message ----- 
From: "Scott Moseley" <scott@xxxxxxxxxx> 
To: "Tesla Coil Mailing List" <tesla@xxxxxxxxxx> 
Sent: Sunday, March 11, 2012 7:43:57 PM 
Subject: [TCML] DC rating for 7KV5 transformer 

Just wondering what rating I should use for caps if my NST is 7.5KV @ 30mA. 
I tried 2 10Kv caps in series, and they burst into flames (and so did the 
$20 I spent on them). Ideas? 

_______________________________________________ 
Tesla mailing list 
Tesla@xxxxxxxxxx 
http://www.pupman.com/mailman/listinfo/tesla 
_______________________________________________ 
Tesla mailing list 
Tesla@xxxxxxxxxx 
http://www.pupman.com/mailman/listinfo/tesla 

_______________________________________________ 
Tesla mailing list 
Tesla@xxxxxxxxxx 
http://www.pupman.com/mailman/listinfo/tesla 
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla