Team
In even more thoughts a double fault condition would need to exist for this
hazard to be an issue
In addition an arc to the RF secondary from the primary would also need to
occur
-----Original Message-----
From: Tesla
Sent: Thursday, September 12, 2013 7:45 AM
To: Tesla Coil Mailing List
Subject: [TCML] Re: TCML Centre tapped mot stacks
Further thought here
Presumably in a fully floated secondary system there is the possibility of
an arc to mains in the outer MOTs placing a 60 Hz component onto the
secondary arcs thereby producing a possible shock hazard if you were in
contact with the secondary arcs (not recommended at any time IMHO at any
power level)
<SNIP>
The only risk I see is that
a flash over will directly connect the HV supply to mains (via the arc) but
given the normal precautions needed with this HV this is not a significant
extra hazard. On this point I've not seen much comment and would welcome any
thoughts the list may have
Best from NZ
Ted