[Home][2018 Index]
Can I use half of the NST so I’m only running 7.5kv? Regards James Janota (727)512-7112 Phone (727)595-6625 Fax > On Jul 15, 2018, at 13:46, jimlux <jimlux@xxxxxxxxxxxxx> wrote: > >> On 7/15/18 5:42 AM, James Janota via Tesla wrote: >> Ok, the old adage about measuring thrice make cutting nice comes to mind here. I have 25 942c6p15k-f in series. These are rated 600v each. Now my father in law who worked as an electrician for NASA and Inland Steel, said that my configuration won’t be enough for a 15kv NST. With my calculator it said 600x25=15000. But he said each one has to be rated for 15kv each. I don’t want a $50. Firecracker. I also have 25 1M resistors, one for each cap. > > No, @ 600V each * 25 = 15kV > You're a little under for a 15kV NST (peak voltage is 20-21kV).. > > >> Please advise. >> Regards >> James Janota >> (727)512-7112 Phone >> (727)595-6625 Fax >> _______________________________________________ >> Tesla mailing list >> Tesla@xxxxxxxxxxxxxxxxxx >> https://www.pupman.com/mailman/listinfo/tesla > > _______________________________________________ > Tesla mailing list > Tesla@xxxxxxxxxxxxxxxxxx > https://www.pupman.com/mailman/listinfo/tesla _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla