[Home][2019 Index]
Message: 12 Date: Tue, 15 Jan 2019 21:08:46 -0500 From: William Fox <wm9fox@xxxxxxxxx> To: tesla@xxxxxxxxxxxxxxxxxx Subject: [TCML] TC Max Spark Length & Output Voltage Message-ID: <419492AB-7182-4979-A6A3-A0771C9F750D@xxxxxxxxx> Content-Type: text/plain; charset=utf-8 Hello, My experience working with high voltage Marx generators (DC uni-potential only devices) showed 100 kV/ft was a good clearance distance for a rod gap or capacitor case to mounting frame. This indicated that a sparkover could occur ~125 kV/ft. Therefore, an 8-ft gap would not likely exceed 1 million volts through air. Experience saw a surface flashover of a 13-ft insulator with ribbed convolutions (skirts or petticoats), at 2.1 million volts (slow switching surge) where the flash occurred over the entire insulator string. At 2.05 million volts, we only saw streamers protruding from the end electrodes. Since that was negative polarity at the power end, when reversing the polarity to positive saw a significant drop in flashover voltage (down to 1.8 million volts) due to clear sparkover, where the higher voltage flashover more closely followed the contours of the insulator. Hoo _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla