Hello Jan, Have you any video of the ground strikes at around 20Kw? It seems that the relatively enclosed bunker area is restricting potential spark length (perhaps a bigger bunker.....?)Phil and I were hitting nearly 13 foot at around 9 to 10Kw (mine 100 bps and Phil's 200 bps synch) although no doubt less bright (especially my 100 bps) than your arcs. I don't think we can manage much more power input with the existing electrical infrastructure but would say that our bunker is less confined than yours and that is the main discrepancy I think. Any chance of a bigger bunker or running it outdoors weather conditions permitting? I would expect it to be a ferocious performer under those circumstances. Regards,Phillip. _____________________________________________________________________________ 14 Broad Street, Stamford, Lincs PE9 1PG Tel: 01780 753008 On Friday, 22 November 2019 13:04:43 GMT, jan@xxxxxxxx <jan@xxxxxxxx> wrote: Hi, I have just upgraded my coil to a little over 20 kW input, formerly it was more like 12 kW. The sparks are certainly fatter, brighter and louder at 20 kW, but they are also less interesting to watch. They tend to immediately stick to the nearest grounded object, the striking ring or the grounded protection net I use around the base. Visually they look like a giant TIG welding arc, burning the same spot without moving. They seem to not want to let go of the first grounded object. The raw power of the streamer is certainly a bit frightening, but the static behaviour is not very interesting. As they seldom ventures outwards, I can´t say much about max length. The distance to the floor is not more than about 6 ft. If I use the lowest ballast tap for about 10 kW, the streamers are constantly probing the surroundings in different directions, with hits to the floor, roof or occasionally objects at larger distance horizontally. They are much thinner, of course, but their behaviour is more interesting. Max length sideways is about 11 ft. If they start from the floor, they tend to climb outwards and then upwards, possibly because heated air movement. Besides the difference in power, the bps is set to about 240 at 10 kW, but more like 340 at 20 kW. Perhaps this also determines the stability of the streamer channel. Anyone who has similar experiences at different power levels? Jan Stockholm, Sweden _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla _______________________________________________ Tesla mailing list Tesla@xxxxxxxxxxxxxxxxxx https://www.pupman.com/mailman/listinfo/tesla