[Home][2021 Index]
Hello TCML! I'm having trouble with my first tesla coil. The specifications are as follows: * 12/30 Transco NST, GFCI removed * Primary coil: 0.25" copper tubing in flat spiral, 0.5" between turns, total 12 turns, 12" total radius from center. Height adjustable. * Secondary coil: 3.5" x 16" on PVC form, 28ga magnet wire, ~ 1100 turns * Topload: 4" dia flex PVC ducting torus, total diameter 18", 10" plywood center. Entire form covered with conductive copper tape. * Capacitor bank: 15x CDE 942C20P15K-F caps in series. 30kV rating, total 10 nF. 10M ohm 1/2W bleeder resistors across each. * Static spark gap of 4x 1" copper tube, microwave AC fan used for quenching * RF grounding rod of 1 ft, solid 1" copper, with 14 ga connection wire * Safety gap calibrated with variac to be just above normal firing voltage * Safety lowpass RC filter (aka ''Terry" filter) of 500 ohm, 100W wirewound resistor and 3x 15kV, 1nF ceramic caps (parallel); one RC set per HV line. F_cutoff ~ 106kHz * All HV connections made with 14ga GTO-15 wire. I've simulated this with JavaTC and it gives me a matching resonant frequencies around 230 kHz. First test was today. Spark gap works like a charm, banging away. Safety gap occasionally fires. Nothing at all on the secondary or topload. No corona, no arcs, CFL bulb put near the coil did not light up. A breakout point was attached, and a large metal object was put near it, and still nothing. Trouble shooting: * Removed the Terry filter. No change. * Changed tap point on primary coil from turn 8 to turn 7, no change. * Continuity checks on the secondary show normal, from topload to grounding strap. Thoughts: * My secondary coil is kind of terrible. First one I ever wound, and it has some wire overlaps. * A second check of my simulation suggests I should actually be using the entire primary coil instead of tapping at turn 8 of 12. Dunno why I did that. Would that have this much of an effect? * The RF grounding on this confuses me a little. I have a large metal strip attached to the bottom of the secondary. This has connections "in" from the safety gap and the terry filter, and "out" to the RF ground rod hammered into the earth. Is this how this is supposed to be wired? Thanks in advance for any advice etc. Glad a list like this exists, as no one in my department at the university (I'm a physics major) has any idea how TCs work. Joshua Thomas -- Joshua Thomas My new email address is: joshuafthomas@xxxxxxxxx Please update your information if you have not already done so.